This mechanical cooling air turnover unit for large, high-bay facilities provides quiet, high-impact air throw to cool the facility floor. Quiet fan design, along with precision design & manufacturing that will ensure that this technology will operate for a long time, providing ROI for the leaders taking on this capital investment for a healthier working environment for their people.
What problem(s) does this solve for the customer?
Comfort (caused by high heat and humidity) problem for their labor force which could be causing turnover, lack of productivity and quality issues.
Product Differentiators
Installation
• Ships in modular sections for easy assembly.
• Requires minimal rigging equipment.
• Floor-mounted indoors, eliminating the need for roof penetrations or structural reinforcements.
Building Application
• Ideal for large open spaces with high ceilings (>20ft).
• These include warehouses, distribution centers, manufacturing plants, recreational facilities, sensitive product storage facilities and more.
Airflow distribution method
• Long horizontal air throws at the correct height remove thermal barriers and ensuring even temperature distribution/air mixing from floor to discharge. This mitigates condensation on building surfaces, equipment, and stored products - preventing costly damages. We don’t have to discharge below the ceiling as long as we clear racking/obstructions to airflow. For example, we can discharge at 23’ in a 40’ high facility if the racking is 17'.
Energy Efficiency
• Efficient destratification decreases the total amount of cooling tons required to effectively condition the space.
• ATO systems typically required fewer air changes per hour compared to ducted systems.
Maintenance & Accessibility
• Coils, fans, controls, filters, controls, electrical and refrigerant connections are easily accessible at the floor-mounted indoor ATO unit.
• Pad-mounted outdoor condensing units serving the ATO are accessible at ground level, nearby utilities and outlets.
Scalability (Mechanical)
• One ATO can replace several RTUs, providing superior scalability.
• Additional ATO units don't require redesign of ductwork. Relocation of units will not require structural modifications.
Scalability (Controls)
• The standard ATO unit controller is upgradable for BACnet applications to simplify integration. Live performance reporting ensures building owners and facility managers that the system is working optimally. Potential issues are simple to identify with the unit controller or integrated BACnet system.
• With the ATO fan array and dual circuited indoor coil, cooling can continue even with